Siemens .NET Client Library for SIMATIC S7 Webserver API
View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens .NET Client Library for SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/<3.3.61, vers:intdot/<3.3.62 (CVE-2026-85114, CVE-2026-85115) CVSS Vendor Equipment v3 7.5 Siemens .NET Client Library for SIMATIC S7 Webserver API 2 Vulnerabilities Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Generation of Error Message Containing Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-85114 Affected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to wri